EDC 355 mass flow controller price

EPC 300 Series Fully Automatic Digital Pressure Controller

  • Full Scale Flow Range(5mbar-100bar)
  • Maximum working pressure up to 100 bar
  • Unaffected by volume changes
  • High precision and repeatability
  • Low pressure loss and less prone to clogging
  • Digital compatible with analog communication
  • High response and low leakage rate
  • Optional real-time display with LCD screen

Metal Seal

Semiconductor

Customizable Products & Solutions

Shipping within 7-14 days

7/24/365 At Your Service

inquiry now

Description of EPC-300 Series Fully Automatic Digital Pressure Controller

The pressure controller EPC integrates a high-precision pressure sensor and an electromagnetic proportional control valve, enabling fast and precise measurement and control of gas pressure. The EPC‑300 series supports RS485 / 0-5 V / 4-20 mA communication, and can realize fully automatic pressure reduction and back pressure control. It is widely used in fields such as petroleum & petrochemical, biomedicine, instrumentation, environmental protection, and vacuum technology.

EPC pressure controller
EPC digital pressure controller

Biosflows EPC-300 EPC-300 Series Fully Automatic Digital Pressure Controller

Pressure reducing controller

Pressure Reducing Controller

The pressure sensor of a pressure reducing controller is located downstream of the proportional valve, and can be used to control the pressure at the outlet or downstream side of the EPC pressure controller.

Back pressure controller

Back Pressure Controller

The pressure sensor of a back-pressure controller is located upstream of the proportional valveand can be used to control the pressure upstream of an EPC pressure controller.

Biosflows EPC-300 Mass Flow Controller and Meters Technical Parameters

Performance Specifications
Control Accuracy<±1%F.S
Repeatability±0.1%F.S
Control stability±0.1%F.S Measurement conditions:1L/min N2 @5MPa
Sensor response time<100 ms
Operating temperature-10~50℃
Medium temperature-10~70℃
Leakage rate<1x10-9 atm.cc/sec He
Electrical Parameters
Power Supply+15~24V dc
Typical Power Consumption5W
Analog Communication0~5V/4~20mA
Digital CommunicationRS-485(Modbus RTU Protocol)
Electrical Interface9-pin D-connector (male)
Mechanical Parameters
Valve TypeNormally Closed
Base Material316L Stainless Steel
Seal MaterialFKM,EPDM,NBR
Gas Port ConnectionAmerican /National Standard Ferrule or VCR Fitting
Protection levelIP40

EPC-300 Selection Guide

EPC-300 Series Mass Flow Controller and Meters Size and Weight

310or320 EDC size

ModelTypleMax pressureControl range
EPC-310-PPressure-reducing controller1MPa2%~100%F.S
EPC-330-PPressure-reducing controller5MPa2%~100%F.S
EPC-350-PPressure-reducing controller10MPa2%~100%F.S
EPC-310-BBack-pressure Controller1MPa2%~100%F.S
EPC-330-BBack-pressure Controller5MPa2%~100%F.S
EPC-350-BBack-pressure Controller10MPa2%~100%F.S
Note: The default pressure value is gauge pressure; if absolute pressure is required, please consult with our sales team.

Features of EPC-300 Series Mass Flow Controller and Meters

New Generation Thermal Gas Sensor Design
The influence of temperature and pressure changes is small, accurate temperature and pressure correction, high linearity, can provide excellent signal-to-noise ratio performance to improve measurement and control accuracy long-term zero point stability.
Superb Dynamic Characteristics
The new microelectronic chip energy-saving technology and innovative multi-level control loop bring super dynamic characteristics. Control performance is adaptive, allowing quick response to setpoint changes without overshoot. Welcome to inquiry in Biosflows.
Flexible and Changeable IO Selection
There are various input/output options of EDC-300 Series Mass Flow Controller and Meters. In addition to various analog signals and standard RS232 communication options, valve cleaning/closing and valve analog output. Multiple fieldbus optional. Get free quotation here.
Wide Flow Range and High Pressure Adaptability
The flow range can be from 3sccm all the way to 1000 SLM, the working pressure is up to 500 psi/100 bar, and the flow measurement and control can be performed under the extremely high pressure difference between upstream and downstream from 6 bar to 70 bar.
Multi-gas and Span Adjustment Function
Choose one device platform to meet the needs of different gases and flow ranges, store and pre-set multiple gas calibration information, so choose our EDC-300 Series Mass Flow Controller, users can easily switch to different gases and ranges with just one device .
Biosflow MFC EDC 300

Aplication of EPC-300 Series Mass Flow Controller and Meters

Gas Control During Fiber Fabrication

Optical fiber preform equipment, optical fiber drawing, and ribbon optical fiber preparation in the optical fiber industry. During the fiber drawing process, the composition and flow of the atmosphere need to be controlled to ensure the quality and performance of the fiber. Need to supply a certain amount of gas, such as protective gas, dry gas, etc. Optical fiber drawing MFC is used to control the flow rate and mixing ratio of the gas to provide the correct atmosphere environment. To ensure that the optical fiber preparation process is stable and repeatable.

Bioreactor Gas Flow Control

Accurate, repeatable and stable airflow is critical to a reliable biological growth process.Especially in R&D environments, a large range of gas flow variations is required to study optimal growth conditions. Benchtop bioreactors require compact gas flow instrumentation. For manufacturers who build bioreactors to customer specifications, there is a need to reduce the number of variations of various flow instrumentation to offset delivery time hurdles. Additionally, pressure data is required to inform bioreactor users of current process conditions.

Catalyst Evaluation Equipment

Catalyst development requires high temperature and pressure to prevent condensation of compounds and to analyze the chemical composition of exhaust gases from reactors. To find out under which conditions a catalyst has optimal performance for a particular chemical reaction, the high pressure range must be dealt with. In the application, the pressure must be accurately controlled and the pressure range is large. Also, the corresponding control device should be able to handle high pressure, high temperature and low flow. The product is perfectly adapted to the conditions in this application.

Gas Flow Control Applications in Analytical Instruments

A common factor in many analytical applications is the need for a small steady gas flow (flow range: 1-1000 sccm), since the gas flow and its changes are directly visible in the measurement, a stable gas flow is important. In analytical equipment, the carrier gas flow directly affects the measurement results. For example, the retention time of a substance in a chromatographic column depends directly on the stability of the fluid. When the flow fluctuates, so does the measurement. This product has short-term and long-term control stability.

Contact Us